Awarded as the best online publication by CIDC
Dear All,
Here i am giving the mix designs as per IS-10262-2009 which gives to change the procedure for calculating the concrete ingredients
Raj Mohammad Khan
M-15 CONCRETE MIX DESIGN |
||
As per IS 10262-2009 & MORT&H |
||
A-1 |
Stipulations for Proportioning | |
1 |
Grade Designation | M15 |
2 |
Type of Cement | OPC 53 grade confirming to IS-12269-1987 |
3 |
Maximum Nominal Aggregate Size | 20 mm |
4 |
Minimum Cement Content (MORT&H 1700-3 A) | 250 kg/m3 |
5 |
Maximum Water Cement Ratio (MORT&H 1700-3 A) | 0.5 |
6 |
Workability (MORT&H 1700-4) | 25 mm (Slump) |
7 |
Exposure Condition | Normal |
8 |
Degree of Supervision | Good |
9 |
Type of Aggregate | Crushed Angular Aggregate |
10 |
Maximum Cement Content (MORT&H Cl. 1703.2) | 540 kg/m3 |
11 |
Chemical Admixture Type | Superplasticiser Confirming to IS-9103 |
A-2 |
Test Data for Materials | |
1 |
Cement Used | Coromandal King OPC 53 grade |
2 |
Sp. Gravity of Cement | 3.15 |
3 |
Sp. Gravity of Water | 1.00 |
4 |
Chemical Admixture | Not Used |
5 |
Sp. Gravity of 20 mm Aggregate | 2.884 |
6 |
Sp. Gravity of 10 mm Aggregate | 2.878 |
7 |
Sp. Gravity of Sand | 2.605 |
8 |
Water Absorption of 20 mm Aggregate | 0.97% |
9 |
Water Absorption of 10 mm Aggregate | 0.83% |
10 |
Water Absorption of Sand | 1.23% |
11 |
Free (Surface) Moisture of 20 mm Aggregate | nil |
12 |
Free (Surface) Moisture of 10 mm Aggregate | nil |
13 |
Free (Surface) Moisture of Sand | nil |
14 |
Sieve Analysis of Individual Coarse Aggregates | Separate Analysis Done |
15 |
Sieve Analysis of Combined Coarse Aggregates | Separate Analysis Done |
15 |
Sp.Gravity of Combined Coarse Aggregates | 2.882 |
16 |
Sieve Analysis of Fine Aggregates | Separate Analysis Done |
A-3 |
Target Strength for Mix Proportioning | |
1 |
Target Mean Strength (MORT&H 1700-5) | 25N/mm2 |
2 |
Characteristic Strength @ 28 days | 15N/mm2 |
A-4 |
Selection of Water Cement Ratio | |
1 |
Maximum Water Cement Ratio (MORT&H 1700-3 A) | 0.5 |
2 |
Adopted Water Cement Ratio | 0.5 |
A-5 |
Selection of Water Content | |
1 |
Maximum Water content (10262-table-2) | 186 Lit. |
2 |
Estimated Water content for 25 mm Slump | 135 Lit. |
3 |
Superplasticiser used | nil |
A-6 |
Calculation of Cement Content | |
1 |
Water Cement Ratio | 0.5 |
2 |
Cement Content (135/0.5) | 270 kg/m3 |
|
Which is greater then 250 kg/m3 | |
A-7 |
Proportion of Volume of Coarse Aggregate & Fine Aggregate Content | |
1 |
Vol. of C.A. as per table 3 of IS 10262 | 62.00% |
2 |
Adopted Vol. of Coarse Aggregate | 65.00% |
|
Adopted Vol. of Fine Aggregate ( 1-0.65) | 35.00% |
A-8 |
Mix Calculations | |
1 |
Volume of Concrete in m3 | 1.00 |
2 |
Volume of Cement in m3 | 0.09 |
|
(Mass of Cement) / (Sp. Gravity of Cement)x1000 | |
3 |
Volume of Water in m3 | 0.135 |
|
(Mass of Water) / (Sp. Gravity of Water)x1000 | |
4 |
Volume of Admixture @ 0% in m3 | nil |
|
(Mass of Admixture)/(Sp. Gravity of Admixture)x1000 | |
5 |
Volume of All in Aggregate in m3 | 0.779 |
|
Sr. no. 1 – (Sr. no. 2+3+4) | |
6 |
Volume of Coarse Aggregate in m3 | 0.507 |
|
Sr. no. 5 x 0.65 | |
7 |
Volume of Fine Aggregate in m3 | 0.273 |
|
Sr. no. 5 x 0.35 | |
A-9 |
Mix Proportions for One Cum of Concrete (SSD Condition) | |
1 |
Mass of Cement in kg/m3 | 270 |
2 |
Mass of Water in kg/m3 | 135 |
3 |
Mass of Fine Aggregate in kg/m3 | 711 |
4 |
Mass of Coarse Aggregate in kg/m3 | 1460 |
|
Mass of 20 mm in kg/m3 | 1051 |
|
Mass of 10 mm in kg/m3 | 409 |
5 |
Mass of Admixture in kg/m3 | nil |
6 |
Water Cement Ratio | 0.5 |
|
We are thankful to Er. Raj M. Khan for sharing this information with us on engineeringcivil.com. We hope this would be of great significance to civil engineers.
If you have a query, you can ask a question here.
what do we understand by workability of M15 grade of concrete ????
mix design of 1:3:6
m-10 mix design
Dear sir i want the mixed propotions of all the ratios in that means like, cement:fine aggregate: course aggregate
How did u obtain the mass ofor fine & coarse Agg. In table A9 Sr. No. 3 & 4.
It is a nice derivation.
for m15,m20,m25 concrte why not i use 33 grade opc .
if i use 33 opc the mix ratio became same as use of 43 grade opc
then what the different between the both?
I request to guide me for my project M 15 MSA 80 with PPC 53 grade concrete mix design
Dz is very useful and awesme
How u found out Volume of Course agg . And fine agg.
Sir plz can tell mi how you reduced water from 186 ltr to 135 ltr from slum 25mm
design mix for wet 1 cum m20