Awarded as the best online publication by CIDC
By
Raj Mohammad Khan
Following table shows the M-20 Mix Designs as per IS-10262-2009, hope this helps all civil engineers here
M-20 CONCRETE MIX DESIGN |
||
As per IS 10262-2009 & MORT&H |
||
A-1 |
Stipulations for Proportioning | |
1 |
Grade Designation | M20 |
2 |
Type of Cement | OPC 53 grade confirming to IS-12269-1987 |
3 |
Maximum Nominal Aggregate Size | 20 mm |
4 |
Minimum Cement Content (MORT&H 1700-3 A) | 250 kg/m3 |
5 |
Maximum Water Cement Ratio (MORT&H 1700-3 A) | 0.5 |
6 |
Workability (MORT&H 1700-4) | 25 mm (Slump) |
7 |
Exposure Condition | Normal |
8 |
Degree of Supervision | Good |
9 |
Type of Aggregate | Crushed Angular Aggregate |
10 |
Maximum Cement Content (MORT&H Cl. 1703.2) | 540 kg/m3 |
11 |
Chemical Admixture Type | Superplasticiser Confirming to IS-9103 |
A-2 |
Test Data for Materials | |
1 |
Cement Used | Coromandal King OPC 53 grade |
2 |
Sp. Gravity of Cement | 3.15 |
3 |
Sp. Gravity of Water | 1.00 |
4 |
Chemical Admixture | Not Used |
5 |
Sp. Gravity of 20 mm Aggregate | 2.884 |
6 |
Sp. Gravity of 10 mm Aggregate | 2.878 |
7 |
Sp. Gravity of Sand | 2.605 |
8 |
Water Absorption of 20 mm Aggregate | 0.97% |
9 |
Water Absorption of 10 mm Aggregate | 0.83% |
10 |
Water Absorption of Sand | 1.23% |
11 |
Free (Surface) Moisture of 20 mm Aggregate | nil |
12 |
Free (Surface) Moisture of 10 mm Aggregate | nil |
13 |
Free (Surface) Moisture of Sand | nil |
14 |
Sieve Analysis of Individual Coarse Aggregates | Separate Analysis Done |
15 |
Sieve Analysis of Combined Coarse Aggregates | Separate Analysis Done |
15 |
Sp. Gravity of Combined Coarse Aggregates | 2.882 |
16 |
Sieve Analysis of Fine Aggregates | Separate Analysis Done |
A-3 |
Target Strength for Mix Proportioning | |
1 |
Target Mean Strength (MORT&H 1700-5) | 30N/mm2 |
2 |
Characteristic Strength @ 28 days | 20N/mm2 |
A-4 |
Selection of Water Cement Ratio | |
1 |
Maximum Water Cement Ratio (MORT&H 1700-3 A) | 0.5 |
2 |
Adopted Water Cement Ratio | 0.5 |
A-5 |
Selection of Water Content | |
1 |
Maximum Water content (10262-table-2) | 186 Lit. |
2 |
Estimated Water content for 25 mm Slump | 145 Lit. |
3 |
Superplasticiser used | nil |
A-6 |
Calculation of Cement Content | |
1 |
Water Cement Ratio | 0.5 |
2 |
Cement Content (145/0.5) | 290 kg/m3 |
|
Which is greater then 250 kg/m3 | |
A-7 |
Proportion of Volume of Coarse Aggregate & Fine Aggregate Content | |
1 |
Vol. of C.A. as per table 3 of IS 10262 | 62.00% |
2 |
Adopted Vol. of Coarse Aggregate | 65.00% |
|
Adopted Vol. of Fine Aggregate ( 1-0.65) | 35.00% |
A-8 |
Mix Calculations | |
1 |
Volume of Concrete in m3 | 1.00 |
2 |
Volume of Cement in m3 | 0.09 |
|
(Mass of Cement) / (Sp. Gravity of Cement)x1000 | |
3 |
Volume of Water in m3 | 0.145 |
|
(Mass of Water) / (Sp. Gravity of Water)x1000 | |
4 |
Volume of Admixture @ 0% in m3 | nil |
|
(Mass of Admixture)/(Sp. Gravity of Admixture)x1000 | |
5 |
Volume of All in Aggregate in m3 | 0.763 |
|
Sr. no. 1 – (Sr. no. 2+3+4) | |
6 |
Volume of Coarse Aggregate in m3 | 0.496 |
|
Sr. no. 5 x 0.65 | |
7 |
Volume of Fine Aggregate in m3 | 0.267 |
|
Sr. no. 5 x 0.35 | |
A-9 |
Mix Proportions for One Cum of Concrete (SSD Condition) | |
1 |
Mass of Cement in kg/m3 | 290 |
2 |
Mass of Water in kg/m3 | 145 |
3 |
Mass of Fine Aggregate in kg/m3 | 696 |
4 |
Mass of Coarse Aggregate in kg/m3 | 1429 |
|
Mass of 20 mm in kg/m3 | 1029 |
|
Mass of 10 mm in kg/m3 | 400 |
5 |
Mass of Admixture in kg/m3 | nil |
6 |
Water Cement Ratio | 0.5 |
If you have a query, you can ask a question here.
SBC of soft rock (morrum)
Sir sbc is 30 how much steel required per sft
Want all latest Civil IS CODE
good afternoon sir and thanks…
how to make Sieve Analysis of Combined Coarse Aggregates?
what is the ratio of M80 CONCRETE AND its properties
Dear Sir,
Good afternoon.Please calculation formula for Fine Aggt.Corse Aggt and cement required for M-30 & M-45 Concrete
I Want Know M-20 Grade Concrete Best Designs For House Slab Purpuse With Aprox price For cu.m
I am my self a builder. The mix proportion given is too high. Cement content comes to be 10.8 bags per cum. Its way too much high. I have designed my self a mix design of M-20, where in I have used 6 bags per cum and the strength achieved is nearly average to M-24.
What is mean by SSD condition?
Sir, we require your cement and mix design manual.How to make sieve analysis of mix metals. How to replace stone powder .
Pl do reply at earliest.
Please let me know that from where we get the limitation of combine gradation.
sir,I want know cement required for m-250&m-200 grade concrete
Sir, we require your cement and mix design manual.
sir plz give me information about ration of mix designing and water cement ration details
like 1 3 6 ratios
how to make problem on based on m20 mix desig show me all steps sir……
Sir, I want to know the qt of cement required for 150 x 150 x150 mm cube of concrete
In this mix design from wer we can getastimated 145 ltr water in which chapter????
IS 383
how to make Sieve Analysis of Combined Coarse Aggregates?