The mix design M-50 grade (Using Admixture –Sikament) provided here is for reference purpose only. Actual site conditions vary and thus this should be adjusted as per the location and other factors.
Parameters for mix design M50
Grade Designation = M-50
Type of cement = O.P.C-43 grade
Brand of cement = Vikram ( Grasim )
Admixture = Sika [Sikament 170 ( H ) ]
Fine Aggregate = Zone-II
Sp. Gravity
Cement = 3.15
Fine Aggregate = 2.61
Coarse Aggregate (20mm) = 2.65
Coarse Aggregate (10mm) = 2.66
Minimum Cement (As per contract) =400 kg / m3
Maximum water cement ratio (As per contract) = 0.45
Mix Calculation: –
1. Target Mean Strength = 50 + ( 5 X 1.65 ) = 58.25 Mpa
2. Selection of water cement ratio:-
Assume water cement ratio = 0.35
3. Calculation of water: –
Approximate water content for 20mm max. Size of aggregate = 180 kg /m3 (As per Table No. 5 , IS : 10262 ). As plasticizer is proposed we can reduce water content by 20%.
Now water content = 180 X 0.8 = 144 kg /m3
5. Calculation for C.A. & F.A.: [ Formula’s can be seen in earlier posts]-
Volume of concrete = 1 m3
Volume of cement = 412 / ( 3.15 X 1000 ) = 0.1308 m3
Volume of water = 144 / ( 1 X 1000 ) = 0.1440 m3
Volume of Admixture = 4.994 / (1.145 X 1000 ) = 0.0043 m3
Total weight of other materials except coarse aggregate = 0.1308 + 0.1440 +0.0043 = 0.2791 m3
Volume of coarse and fine aggregate = 1 – 0.2791 = 0.7209 m3
Volume of F.A. = 0.7209 X 0.33 = 0.2379 m3 (Assuming 33% by volume of total aggregate )
Volume of C.A. = 0.7209 – 0.2379 = 0.4830 m3
Therefore weight of F.A. = 0.2379 X 2.61 X 1000 = 620.919 kg/ m3
Say weight of F.A. = 621 kg/ m3
Therefore weight of C.A. = 0.4830 X 2.655 X 1000 = 1282.365 kg/ m3
Say weight of C.A. = 1284 kg/ m3
Considering 20 mm: 10mm = 0.55: 0.45
20mm = 706 kg .
10mm = 578 kg .
Hence Mix details per m3
Increasing cement, water, admixture by 2.5% for this trial
Cement = 412 X 1.025 = 422 kg
Water = 144 X 1.025 = 147.6 kg
Fine aggregate = 621 kg
Coarse aggregate 20 mm = 706 kg
Coarse aggregate 10 mm = 578 kg
Admixture = 1.2 % by weight of cement = 5.064 kg.
Water: cement: F.A.: C.A. = 0.35: 1: 1.472: 3.043
We are thankful to Er Gurjeet Singh for this valuable information.
If you have a query, you can ask a question here.
Dear Sir,
Kindly send me Mix design for M-55 grade paver blocks,which is made up of only crushed sand with 0-4 mm & cement.
Dear sir,
Kindly send me mix design M – 45 grade
Dear Sir
Please send me article regarding preparation of MIx desing
Dear Sir,
Kindly send me Mix design for M-50 grade using waste glass in replacement of aggregate
Sir,we have considered vol of conc=1.Then we have deducted the total vol of cement,water & admixture from 1.but we have not considered the entrapped air.If maximum size of coarse aggregate used say,20 mm,then entrapped air will be 2%.Enteapped air will be taken into account or not?Please help in this regard.-ARIJIT ROY
can we desing concrete mix design with 100% CRF, if so what is ITS RELIABILITY AND DRABILITY
Dear sir
kindly send me mix design for M-15,M-20,M-25,M-30,M-35,M-40,M-50 grades using wast glass of aggregate
sir please send me the design of road work mix design by using 40mm size
kindly send me mix design for M-15,M-20,M-25,M-30,M-35,M-40,M-50 grades using ppc and fly ash
sir,
please send me mix design for m 35 with crushed sand because non avalibality of sand in uor locality please do needfull help
Dear Sir,
Can you please send me detailed Mix design as per IS codes
kindly send me mix design for M-15,M-20,M-25,M-30,M-35,M-40,M-50 grades using ppc and fly ash
plz send mix design of M-45 and M-35 .
SIR PLZ SEND CONCRETE MIX DESIGN FOR M-10,M-15,M-20,M25,M30,M35,M40,M45,M50,M60,M70……..
what is minimum cement content for M35, M40 & M60 Grade of Concrete
I WANT TO KNOW @ CEMENT CONSUMPTION FOR GRADE M-5 TO M – 60
The easiest way for doing Mix-design. 1- a/100 = 1/1000(W+C/3.15+ FA/ PXSqFA) for fine aggregate. 1-a/100=1/1000(W+C/3.15+CA/PX1-SqCA)
Dear sir
Plz send me m-25grade using jaypee opc-43cement
m-25 1:1:2
Hi Mr Reddy,
Please suggest if we get concrete slump more then the required slupm for example required slamp 100 (+,- 25) and also suggest the which material used to controle
Dear all,
Please send me a High flow concrete Parameters for mix design M70