Awarded as the best online publication by CIDC
Following are the IS codes which are used for standardization of Fire Fighting including standardization in the field of Fire Fighting Equipment Including Water Fittings, Fire Fighting Units, Fire Detection And Fire Alarm Systems, Helmets, Equipment For Fire Protection And Fire Fighting, Personal Safety – Protective Clothing and Equipment.
IS 884:1985 Specification for first-aid hose reel for fire fighting
IS 901:1988 Specification for couplings, double male and double female, instantaneous pattern for fire fighting
IS 902:1992 Specification for suction hose couplings for fire fighting purposes
IS 903:1993 Specification for fire hose delivery couplings, branch pipe, nozzles and nozzlespanner
IS 904:1983 Specification for 2-way and 3-way suction collecting heads for fire fighting purposes
IS 905:1980 Specification for delivery breechings, dividing and collecting instantaneous pattern for fire fighting purposes
IS 906:1988 Specification for revolving branch pipe for fire fighting
IS 907:1984 Specification for suction strainers, cylindrical type for fire fighting purposes
IS 908:1975 Specification for fire hydrant, stand post type
IS 909:1992 Specification for underground fire hydrant, sluice valve type
IS 910:1980 Specification for combined key for hydrant, hydrant cover and lower valve
IS 926:1985 Specification for fireman’s axe
IS 937:1981 Specification for washers for water fittings for fire fighting purposes
IS 939:1977 Specification for snatch block for use with fibre rope for fire brigade use
IS 940:2003 Specification for portable fire extinguisher, water type (gas cartridge)
IS 941:1985 Specification for blower and exhauster for fire fighting
IS 942:1982 Functional requirements for 275 l/min portable pump set for fire fighting
IS 943:1979 Functional requirements for 680-l/min trailer pump for fire brigade use
IS 944:1979 Functional requirements for 1800-l/min trailer pump for fire brigade use
IS 947:1985 Functional requirements for towing tender for trailer fire pump for fire brigade use
IS 948:1983 Functional requirements for water tender type `A’ for fire brigade use
IS 949:1985 Functional requirements for emergency (rescue) tender for fire brigade use
IS 950:1980 Functional requirements for water tender, for fire brigade use
IS 951:2003 Functional requirements for crash tender for air fields
IS 952:1986 Specification for fognozzle for fire brigade use
IS 955:1980 Functional requirements for dry powder tender for fire brigade use (150 kg capacity)
IS 956:2004 Functional requirements for rescue tender for air fields
IS 957:1967 Specification for control van for fire brigade use
IS 1941(Part 1):1976 Functional requirements for electric motor sirens: Part 1 AC, 3 Phase 50 hz, 415 volts type
IS 2097:1983 Specification for foam making branch pipe
IS 2171:1999 Specification for portable fire extinguishers,dry powder (cartridge type)
IS 2175:1988 Specification for heat sensitive fire detectors for use in automatic fire alarmsystem
IS 2189:2008 ISO/TR 7240-14 Code of practice for selection, installation and maintenance of automatic fire detection and alarm system
IS 2546:1974 Specification for galvanized mild steel fire bucket
IS 2696:1974 Functional requirements for 1125-l/min light fire engine (Superseding IS 938)
IS 2745:1983 Specification for non-metal helmet for firemen and civil defence personnel
IS 2871:1983 Specification for branch pipe, universal for fire fighting purposes
IS 2878:2004 Specification for fire extinguisher, carbon dioxide type (portable and trolly mounted )
IS 2925:1984 | ISO 3873 Specification for industrial safety helmets
IS 2930:1980 Functional requirements for hose laying tender for fire brigade use
IS 3582:1984 Specification for basket strainers for fire fighting purposes (cylindrical type)
IS 3744:1985 Specification for hose binding machine
IS 3844:1989 Code of practice for installation and maintenance of internal fire hydrants and hose reels on premises
IS 4151:1993 Specification for protective helmets for motorcycle riders
IS 4308:2003 Specification for dry chemical powder for fighting B and C Class fires
IS 4571:1977 Specification for aluminium extension ladders for fire brigade use
IS 4643:1984 Specification for suction wrenches for fire brigade use
IS 4861:1984 Specification for dry powder for fighting fires in burning metals
IS 4862(Part 1):1986 Specification for portable fire extinguishers for aircraft : Part 1 Halon 1211 Type
IS 4927:1992 Specification for unlined flax canvas hose for fire fighting
IS 4928:1986 Specification for delivery valve for centrifugal fire pump outlets
IS 4947:2006 Specification for gas cartridges for use in fire extinguishers
IS 4989:2006 Foam concentrate for producing mechanical foam for fire fighting – Specification [Amalgamating IS 4989(Part 1):1985, IS 4989(Part 2):1984 and IS 4989(Part 3):1987]
IS 4989(Part 4):2003 Specification for multipurpose aqueous film forming foam liquid concentrate for extinguishing hydrocarbon and polar solvent fires
IS 5131:2002 Specification for dividing breeching with control for fire brigade use
IS 5290:1993 Specification for landing valves
IS 5486:1985 Specification for quick release knife
IS 5505:1985 Specification for multi-edged rescue axe (non-wedging)
IS 5612(Part 1):1977 Specification for hose-clamps and hose-bandages for fire brigade use: Part 1 Hose-clamps
IS 5612(Part 2):1977 Specification for hose-clamps and hose bandages for fire brigade use: Part 2 Hose bandages
IS 5714:1981 Specification for hydrant, stand-pipe for fire fighting
IS 5888:1970 Code of practice for design and construction of fire service drill-tower
IS 5896(Part 1):1970 Code of practice for selection, operation and maintenance of special fire fighting appliances: Part 1 Combined foam and CO2 crash tender
IS 5896(Part 3):1975 Code of practice for selection, operation and maintenance of fire fighting appliances: Part 3 Turntable ladders
IS 6026:1985 Specification for hand-operated sirens
IS 6067:1983 Functional requirements for water tender type `X’ for fire brigadeuse
IS 6070:1983 Code of practice for selection, operation and maintenance of trailer fire pumps, portable pumps, water tenders and motor fire engines
IS 6234:2003 Specification for portable fire extinguishers,water type (stored pressure)
IS 7673:2004| ISO 8421-1 revision Glossary of terms for fire fighting equipment
IS 7692:1993 Specification for headforms for testing of helmets
IS 8090:1976 Specification for couplings,branch pipe,nozzle, used in hose reel tubing for fire fighting
IS 8096:1992 Specification for fire beaters
IS 8149:1994 Functional requirements for twin CO2 fire extinguishers (trolley mounted)
IS 8423:1994 Specification for controlled percolating hose for fire fighting
IS 8442:2008 Functional requirements for stand post type water monitor for fire fighting
IS 9562:1980 Specification for non-metal helmet for police force
IS 9668:1990 Code of practice for provision and maintenance of water supplies and fire fighting
IS 9695:1980 Methods of sampling of helmets
IS 9972:2002 Specification for automatic sprinkler heads for fire protection service
IS 9973:1981 Specification for visor for scooter helmets
IS 9995:1981 Specification for visor for non-metal police and firemen’s helmets
IS 10204:2001 Specification for portable fire extinguisher mechanical foam type
IS 10460:1983 Functional requirements for small foam tender for fire brigade use
IS 10658:1999 Specification for higher capacity dry powder fire extinguisher (trolley mounted)
IS 10993:1984 Functional requirements for 2000-kg dry powder tender for fire brigade use
IS 11101:1984 Specification for extended branch pipe for fire brigade use
IS 11108:1984 Specification for portable fire extinguisher halons- 1211 type
IS 11360:1985 Specification for smoke detectors for use in automatic electrical fire alarm system
IS 11833:1986 Specification for dry powder fire extinguisher for metal fires
IS 12717:1989 Functional requirements of fire fighting equipment – High capacity portable pumpset (1100-1600 L/min)
IS 12796:1989 Specification for fire rake
IS 12805:1989 Tool Mcleod for fighting forest fires
IS 12835(Part 1)| ISO 7203-1 :1989 Code of practice for design and installation of fixed foam fire extinguishing system: Part 1 Low expansion foam
IS 12853:1989 Specification for pulaski tool for forest fire
IS 12859:1989 Specification for brush hook for forest fire
IS 12861:1989 Specification for double bit axe for forest fire
IS 12862:1989 Specification for fire fighting shovel for forest fires
IS 13039:1991 Code of practice for external hydrant systems provision and maintenance
IS 13385:1992 Specification for fire extinguisher- 50 litre capacity wheel mounted water type (Gas Cartridge)
IS 13386:1992 Specification for fire extinguisher 50 litre capacity mechanical foam type
IS 13849:1993 Specification for portable fire extinguisher dry powder type (stored pressure)
IS 14609:1999| ISO 7202 Specification for dry chemical powder for fighting ABC Class fires
IS 14851:2000 Code of practice for maintenance of fire hose
IS 14933:2001 Specification for high pressure fire fighting hose
IS 14951:2001 Specification for fire extinguisher, 135 litre capacity mechanical foam type
IS 15051:2001 High pressure fire hose delivery couplings – Specification
IS 15105:2002| ISO 6182-1 Design and installation of fixed automatic sprinkler fire extinguishing systems – Specification
IS 15220:2002| ISO 7201-1 Specification for halon 1211 and halon 1301 – halogented hydrocarbon – fire extinguishing media for fire protection
IS 15221:2002| ISO 7201-2 Code of practice for safe handling and transfer procedure of halon 1121 and halon 1301- (halogonated hydrocarbon) – fire extinguishing media
IS 15222:2002| ISO 5923 Specification for carbon-dioxide as fire extinguishing media for fire protection
IS 15301:2003 Code of practice for installation and maintenance of fire fighting pump
IS 15325:2003 Code of practice for design and installation of fixed automatic high and medium velocity water spray system
IS 15397:2003 Specification for portable fire extinguisher mechanical foam type (stored pressure)
IS 15493:2004| ISO 14520-1 Gaseous fire extinguishing systems – General requirements
IS 15496:2004 Inspection and maintenance of gaseous fire extinguishing systems – Code of practice
IS 15497:2004| ISO 14520-12 Gaseous fire extinguishing systems T IG 01 extinguishing systems
IS 15501:2004| ISO 14520-15 Gaseous fire extinguishing systems IG 541 extinguishing systems
IS 15505:2004| ISO 14520-6 Gaseous fire extinguishing systems – HCFC Blend A extinguishing systems
IS 15506:2004| ISO 14520-14 Gaseous fire exginsuishing systems – IG 55 – extinguishing systems
IS 15517:2004| ISO 14520-9 Gaseous fire extinguishing systems – HFC 227ea (Hepta Fluoro Propane)extinguishing systems
IS 15519:2004 Water mist fire protection systems – System design, installation and commissioning
IS 15525:2004| ISO 14520-13 Gaseous fire extinguishing systems – IG 100 extinguishing systems
IS 15682:2006 Fire fighting vehicle and equipment – Symbols for operator controls and other display
IS 15683:2006 Portable fire extinguishers – Performance and construction – Specification
IS 15811:2008 Long-range water-cum-foam monitor with self-inducting, aspirating and non-aspirating jet and spray/fog nozzle for fire fighting – Specification
IS 15821:2008 Gaseous fire extinguishing system – Physical properties and system design – CF3I Extinghishant
IS 15835:2009 Gaseous Fire Extinguishing Systems HCFC – 125 Extinguishing Systems
This IS Code list is updated as on December 23, 2011 on engineeringcivil.com. We have tried to list all Indian Standard Codes for Fire Fighting, but might have missed a few. If you know any code which we have missed, just comment below and help us add it in this list.
If you have a query, you can ask a question here.
Just need information about hydrant line testing prosijur & its IS standared
Dear sir,
kindly give information about Maintenance and Installation Specifications of Fire Water Monitor regards
Sir,
Please give refrence where i can get new IS code description for Fire Extinguishers in 2012??????
Dear there is one new system is 16018:2012 for wheeled fire extinguishers performance and construction -specification
YES. “There is one new system is 16018:2012 for wheeled fire extinguishers performance and construction -specification” and same shall be updated in the list.
Can anyone help me out with a copy of norms to be followed for firefighting in warehouses
can anyone tell about what are the parameters should be known for the fire fighting engineer.
what is standard for painting of fire water pipeline and duration of painting the ring main
what is standard for painting of fire water pipeline and duration of painting the ring main
Dear Sir,
Are there any standards for fire water quality i.e. permissible limits of water quality like pH, TDS, oil content, etc ?
Firefighting training is a requirement under whihc NFPA or OSHA code.